2019-nCOV IgG/IgM Peranti Ujian Pantas (Darah/Serum/Plasma)
【Kepekaan dan Kekhususan】
Untuk ujian IgG:
| Kaedah | RT-PCR | Jumlah Keputusan | ||
| 2019-nCOV IgG/IgM Peranti Ujian Pantas (Darah keseluruhan/Serum/Plasma) | Keputusan | Positif | Negatif | |
| Positif | 233 | 2 | 235 | |
| Negatif | 25 | 287 | 312 | |
| Jumlah Keputusan | 258 | 289 | 547 | |
Sensitiviti Relatif:233/258=90.31%(95%CI*:86.04%-93.40%)
Kekhususan Relatif:287/289=99.31% (95%CI*:97.34%-99.98%)
Ketepatan:520/547=95.06% (95%CI*: 92.89%-96.61%)
*Selang Keyakinan
Untuk ujian IgM
| Kaedah | RT-PCR | Jumlah Keputusan | ||
| 2019-nCOV IgG/IgM Peranti Ujian Pantas (Darah keseluruhan/Serum/Plasma) | Keputusan | Positif | Negatif | |
| Positif | 223 | 7 | 230 | |
| Negatif | 35 | 282 | 317 | |
| Jumlah Keputusan | 258 | 289 | 547 | |
Sensitiviti Relatif:223/258=86.43% (95%CI*:81.68%-90.11%)
Kekhususan Relatif:282/289=97.58% (95%CI*: 94.99%-98.92%)
Ketepatan:505/547=92.32% (95%CI*: 89.76%-94.29%)
*Selang Keyakinan
【ARAHAN UNTUK PENGGUNAAN】

Tulis mesej anda di sini dan hantarkan kepada kami